CT7 BDD Module

BDD anode L240*W130*H3mm: 7pcs*1 set

Titanium cathode L318*W129*H1mm:

8 pieces*1 set, working area: 0.4368m2

Product Description:

BDD Pilot Module

The BDD pilot module is a pilot module made by using anti-corrosion material PP as the container carrier, using a box or barrel container to load several BDD electrodes as anodes and metal titanium plates as cathodes to test target solutions (such as The electrolysis effect of industrial wastewater) is used to determine the treatment results of various indicators in the electrolytic solution, to obtain the best electrolysis effect of the target solution with the optimal effect. It can be used as a component of the subsequent project module to determine the subsequent project Treatment plan.

There are currently three solutions for handling pilot modules:

 

Single module solution

BDD anode: L240*W130*H3mm  7 pieces*1 set

Titanium cathode: L324*W150*H1.5mm 8 pieces*1 set

Sink:L630*W206*H184mm 1pc

Two-module solution

BDD anode: L240*W130*H3mm 7 pieces *2 sets

Titanium cathode: L324*W150*H1.5mm 8 pieces*2 sets

Sink: L1188*W354*H218mm 1pc

Double-module barrel solution

BDD anode: L240*W130*H3mm 7 pieces*2 sets

Titanium cathode: L324*W150*H1.5mm 8 pieces*2 sets

Sink: L776*W600*H1300mm 1

Chassis L600*W600*H100mm 1pc

 

Operating Parameters

 

 Power Parameters

  1. Rated current density: 150mA/cm2
  2. Voltage: Passive voltage, different medium (water quality) voltage is different. (The current can be controlled)

 

 Equipment Operating Parameters

  1. Water flow speed: 10 tons/hour
  2. Pressure: not detected, normal pressure
  3. Temperature: 0-80 degrees
  4. pH value: 1-14
  5. The conductivity of the medium (sewage) shall not be lower than 5000us/cm, otherwise, the established effect may not be achieved.